Fabral is a leader in the metal cladding industry for residential, light commercial, and agricultural applications. Frabral's selection of Exposed Fastener Panels caters to the requirements of different projects, offering high-performance, efficiency, and aesthetic appeal.
| |
Hefti-Rib 288 (HR-288) - Minimum Roof Slope: 1:12
- Hail Resistance: UL2218, Class 4
- Fire Resistance: UL790, Class A
- Wind Uplift Test Rating: UL580 Class 1-90, #169
- Wind Uplift: Factory Mutal FM: Class 1 -150
- Maximum Panel Length: 45′
- Minimum Panel Length: 6′
| Mighti-Rib® - Minimum Roof Slope: 1:12
- Hail Resistance: UL2218, Class 4
- Fire Resistance: UL790, Class A
- Wind Uplift Test Rating: UL580 Class 1-90, #169
- Wind Uplift: Factory Mutal FM: Class 1 -150
- Maximum Panel Length: 45′
- Minimum Panel Length: 6′
|
| |
Fabrib - Minimum Roof Slope: 2 1/2: 12
- Hail Resistance: UL2218, Class 4
- Fire Resistance: UL790, Class A
- Maximum Panel Length: 30′ steel, 17′ aluminum
- Minimum Panel Length: 6′
| Hefti-Rib® - Maximum Panel Length: 45′
- Minimum Panel Length: 6′
- Roof Slope: Minimum required - 2:12
- Purlin Spacing: Maximum - 5' on-center
- Panel Length: Maximum - 65' Minimum - 4'
- Factory Curving: Minimum radius 10
|
| |
V-Beam - Maximum Panel Length: 45′
- Minimum Panel Length: 6′
- Roof Slope: Minimum required - 2:12
- Purlin Spacing: Maximum – 4’ on-center
- Field Curving: Minimum radius 200’
- Panel Length: Maximum - 45’ (steel) 16’ (alum.) Minimum - 4’
- Panel Width: 32” (steel) 42 2⁄3” (alum.)
| U-Panel - Maximum Panel Length: 45′
- Minimum Panel Length: 4′
|
| |
PBU Panel - Roof Slope: Minimum required - 2.5:12 (PBU)
- Purlin Spacing: Maximum - 5' on-center
- Reverse Run Available
- Perforated Options Available
- Panel Length: Maximum - 45' Minimum - 6'
- Panel Width: 36" Coverage
| PBR - Roof Slope: Minimum required - 1:12 (PBR)
- Purlin Spacing: Maximum - 5' on-center
- Reverse Run Available
- Perforated Options Available
- Panel Length: Maximum - 45' Minimum - 6'
- Panel Width: 36" Coverage
|
| |
R-Panel - Hail Resistance: UL2218, Class 4
- Fire Resistance: UL790, Class A
- Maximum Panel Length: Custom cut to lengths up to 40’
- Minimum Panel Length: 4′
| 1/2″ Corrugated - Roof Slope: Minimum required - 2 1/2:12
- Factory Curving: Minimum radius 15’
- Panel Length: Maximum - 45’ Minimum - 6’
- Panel Width: Maximum - 51 5/16” Minimum - 34”
|
| |
7/8″ Corrugated - Panel Width: Maximum – 48” Minimum – 26”
- Panel Length: Maximum – 45’ Minimum – 6’
- Factory Curving: Minimum radius 10’
- Roof Slope: Minimum required – 2 1/2:12
- Perforation available upon request
| 4” Rib® - Perforation available upon request
- Roof Slope: Minimum required - 2 1/2:12
- Panel Length: Maximum - 45' Minimum - 6'
- Panel Width Options: 48", 32"
- Panel Variation 8” Rib is Available
|