Flat Roof Access Hatch Comfort Swing | LAMILUX
  1. ArchDaily
  2. Products
  3. Skylights
  4. Flat Roof Access Hatch Comfort Swing

Flat Roof Access Hatch Comfort Swing | LAMILUX

  • Available in

  • Use

    Roof exit hatch, skylight
  • Applications

    Roofs
  • Characteristics

    Flat window, self-cleaning, noise-optimized retractable sliders for shading, emergency stop function
  • Sizes

    Top roof edge dimensions: 100 cm x 300 cm or 100 cm x 350 cm | Top element height: 41cm on eaves, 50cm on opposite long side
  • Certification

    Fall-through proof according to DIN 18008-6, Resistance to external fire exposure from flying sparks and radiant heat with classification Broof(t1) according to DIN EN 13501-5, compliance with DIN 18234 without additional measures (prevention of fire expansion on the flat roof)

4 Product Files

1 General Catalog

By downloading any file you agree to the Terms of Use, Privacy Policy and to the communication of your data to the brand from which you download catalogs and files.
The product has been saved to the folder: My Downloaded Products
LAMILUX Logo

Contact manufacturer

LAMILUX

LAMILUX Logo

Contact manufacturer

LAMILUX

More from LAMILUX

Website Phone

More about this product

The LAMILUX Flat Roof Exit Comfort Swing opens its300 or 350 cm long glass elements by key switch hydraulically. To configure BIM-, CAD- and product data for this product according to your individual requirements click here.

Design and Comfort

  • Winner of the German Design Award 2020 in the Category Special Mention
  • Generous daylight incidence
  • Convenient access to the roof terrace via stairs (on-site)
  • Flat roof exit opens 84° in approx. 25 seconds
  • Folding mechanism provides more space on the roof terrace
  • Self-cleaning due to inclined upstand
  • Top element and flat transition from frame to glazing
  • Stepless opening by hydraulic cylinder
  • Variety of colors according to RAL card (edging profiles and reveal area)
  • Leaf system, motor opener and top element are completely pre-assembled at the factory
  • Opening side DIN left or DIN right selectable when ordering

Safety

  • Emergency stop function during closing by light barrier
  • Closing and opening of the element possible via optional key switch
  • Can be opened or closed during a power failure by manual operation with a hand lever
  • As a standard: Outer pane TSG, inner pane LSG

Energy Efficiency

  • Complete construction without thermal bridges
  • Completely thermally insulated upstand
  • Can be equipped with the highest quality functional glass
  • Minimized risk of condensation

The LAMILUX Flat Roof Exit Comfort Swing has optimal isothermal curves that minimize the condensation risk. The roof hatch also has high thermal insulation in the joint area.

Glazing Types

All glazing types have an Ug-value of 0,6 W/(m²K) and 39 dB soundproofing

Designation Translucency Total energy transmission
Heat protection glazing W110 72 % 51 %
Heat protection glazing W303 49 % 50 %
Solar protection glazing 60/30 S117 55 % 30 %
Solar protection glazing 60/30 S118 37 % 27 %
Solar protection glazing 50/25 S121 47 % 26 %
Solar protection glazing 50/25 S122 31 % 23 %
Solar protection glazing 70/37 S125 62 % 34 %
Solar protection glazing 70/37 S126 42 % 34 %

Sun Protection

Daylight and solar heat have the potential to increase light and heat energy inside buildings which can be used to save costs for heating and artificial lighting. This needs to be controlled by adjustable shading systems. The external shading system for LAMILUX Flat Roof Exit Comfort Swing is suitable for this. With noise-optimized retractable sliders, the external awning can be easily extended using push buttons or a radio remote control allowing optimum control of the amount of natural light entering the room. The cable routing is concealed and integrated in the top element.

Opening Drives

Opening takes place over the leaf using a hydraulic cylinder on each narrow side, this is controlled by an electrically operated hydraulic unit (230 V). The Flat Roof Exit Comfort has a limit switch which monitors the opening on the opposite narrow side of the exit and a light barrier for monitoring the exit area of the element. To open the roof hatch, the hydraulic unit is controlled via a key switch with a dead man's switch.

Top Element

The top element forms the base for the construction and creates an ideal thermal connection to the building structure. The extension element is made of steel insulated throughout with mineral wool. The inside is covered with a coated aluminum sheet in any RAL Classic color and the outside with white pigmented GRP. The top element complies with DIN 18234 - prevention of fire expansion on the roof without additional measures.

The top element has a 5° inclination, which supports an ideal self-cleaning of the element.

Product gallery

Latest Catalogs and Files

By downloading any file you agree to the Terms of Use, Privacy Policy and to the communication of your data to the brand from which you download catalogs and files.
See All
LAMILUX Logo

Contact manufacturer

LAMILUX

LAMILUX Logo

Contact manufacturer

LAMILUX

More from

LAMILUX

Website Phone

Contact manufacturer

LAMILUX Logo

Contact manufacturer

LAMILUX

Related Products

View more related products »
Flat Roof Access Hatch Comfort Solo

Flat Roof Access Hatch Comfort Solo

LAMILUX
Glass Skylight F100 Circular

Glass Skylight F100 Circular

LAMILUX
Contact us